Surveillance Surge Arrester
Home » Lightning Products » IT Surge Protection » Surveillance Surge Arrester
Instruction
♦ TS-VCP2 IP Camera Surge Protector is designed to protect power lines and video lines of surveillance devices from surge damages, such as surveillance video receiver and camera and so on.These products are widely used in bank surveillance systems(CCTV system), residential security systems,surveillance devices or school security corporation & roads.
♦ Product Size (with BNC connector)
♦ INPUT & OUTPUT with BNC connector
♦ INPUT & OUTPUT with RJ45 connector
♦ Technical Data
Model |
TS-VCP2 |
||||||
Protection lines |
Video Line (BNC) |
Video Line (RJ45) |
Power Supply line |
||||
Nominal voltage |
Un |
5V- |
48V- |
220V- |
48V- |
24V- |
12V- |
Lightning impulse current(10/350) |
Iimp |
0.5KA |
0.5KA |
--- |
--- |
--- |
--- |
Nominal discharge current (8/20) |
In |
2.5KA(line-shield) 5KA (shield-PG) |
2.5KA (line-shield) 5KA (shield-PG) |
5KA |
5KA |
5KA |
5KA |
Max. discharge current (8/20) |
Imax |
5KA (line-shield) 10KA (shield-PG) |
5KA (line-shield) 10KA (shield-PG) |
10KA |
10KA |
10KA |
10KA |
Voltage protection level at In |
Up |
≤25V (line- shield) ≤25V (shield-PG) |
≤130V(line- shield) ≤130V (shield-PG) |
≤950V (L-N) |
≤450V (L-N) |
≤300V (L-N) |
≤240V (L-N) |
Voltage protection level at 1kV/µs |
Up |
≤25V (line- shield) ≤25V (shield-PG) |
≤145V(line-shield) ≤145V (shield-PG) |
--- |
--- |
--- |
--- |
Response time |
tA |
≤1ns (line- shield) ≤100ns (shield-PG) |
≤1ns (line- shield) ≤100ns (shield-PG) |
≤25ns |
≤25ns |
≤25ns |
≤25ns |
Bandwidth |
fG |
10MHz |
165MHz |
--- |
--- |
--- |
--- |
Max. data transmission rate |
Vs |
16Mbits/s |
100Mbits/s |
--- |
--- |
--- |
--- |
Series impedance |
|
--- |
--- |
--- |
--- |
--- |
--- |
Insertion lose |
|
0.4dB |
0.4dB |
--- |
--- |
--- |
--- |
Connection (input/output) |
|
BNC socket/plug |
RJ45 socket/plug |
Screw |
|||
Operating temperature range |
|
-40°C...+80°C |
|||||
Relative humidity: |
|
95% (25°C) |
|||||
Earthing via |
|
Earthing screw |
|||||
Enclosure material |
|
Aluminum |
|||||
Standards |
|
IEC 61643-21; GB 18802.21; YD/T 1542 |
|||||
Certification |
|
CE(LVD,EMC) |
♦ MAIN CHARACTER
1, Integrated protection for power lines and video signal lines of the camera
2, High discharge capacity, low voltage protection level
3, Quick response, multilevel protection ,small interference to transmission signal
INSTALLATION INSTRUCTION 1. This Camera Surge Protector is connected in series to the protected device. 2. The out terminal should be connected to the protected devices. Note: The “IN” terminal power supply must be installed with a backup fuse; 3. Earth lead should be connected to the earthing system, ideally using 2.5mm² cable, the cable should be as short as possible 4. On power up, the green light will be on. Regularly inspect the operating status, especially after lightning, once the communication is off, electrician should check/replace the Camera Surge Protector.
|
INSTALLATION DIAGRAM |
WARNING: 1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations. 2. It is recommended that installation should be done under power off condition. |
- CONTACT US
- 0086 13926098193
- 0086 20 28819702 EXT 27806
- [email protected]
- Hongdiyuan Industrial Park, Wufeng Avenue, Linjiang Town, Jiangdong New District, Heyuan, Guangdong,P.R.C.
- http://www.tslpro.com
- +86 13926098193
- F13926098193
- tslpro.tstlp