• Product Name :

    TS-VCP3N Surveillance Camera Surge Protection

  • Instruction

    TS-VCP3N 3 in 1  Surveillance Camera Surge Protection is designed to protect power supply lines, control signal lines and video signal lines of surveillance devices from surge damages, widely applied in surveillance systems. such as surveillance video receiver, high speed dome camera, fixed camera and so on.

    ♦ Product Size ( BNC / Terminal connector)

    TS-VCP3N-Surveillance-Camera-Surge-Protection-In-China

     

    TS-VCP3N-Surveillance-Camera-Surge-Protection-Supplier

     

    ♦ Technical Data 

    Model 

    TS-VCP3N 

    Protection lines 

    Video Line 

    Controlling Line 

    Power Supply line 

    Nominal voltage 

    Un

    5V- 

    12V- 

    220V- 

    48V-

    24V-

    12V-

    Lightning impulse current(10/350)

    Iimp

    0.5KA

    2KA

    ---

    ---

    ---

    ---

    Nominal discharge current (8/20) 

    In

    2.5KA(line-shield)

    5KA (shield-PG) 

    5KA (line-shield) 

    5KA (shield-PG) 

    5KA

    5KA

    5KA

    5KA

    Max. discharge current (8/20)

    Imax

    5KA (line-shield) 

    10KA (shield-PG)

    10KA (line-shield) 

    10KA (shield-PG)

    10KA

    10KA

    10KA

    10KA

    Voltage protection level at In 

    Up

    ≤25V (line- shield)

    ≤25V (shield-PG) 

    ≤25V (line- shield) 

    ≤25V (shield-PG) 

    ≤950V(L-N)

    ≤450V

    (L-N)

    ≤300V

    (L-N)

    ≤240V

    (L-N)

    Voltage protection level at 1kV/µs

    Up

    ≤25V (line- shield)

    ≤25V (shield-PG)

    ≤19V (line- shield)

    ≤19V (shield-PG)

    ---

    ---

    ---

    ---

    Response time

    tA

    ≤1ns (line- shield)

    ≤100ns(shield-PG)

    ≤1ns (line- shield)

    ≤100ns (shield-PG)

    ≤25ns

    ≤25ns

    ≤25ns

    ≤25ns

    Bandwidth

    fG

    10MHz

    2.9MHz

    ---

    ---

    ---

    ---

    Max. data transmission rate

    Vs

    16Mbits/s

    ---

    ---

    ---

    ---

    ---

    Series impedance

     

    ---

    1.9Ω

    ---

    ---

    ---

    ---

    Insertion lose

     

    0.4dB

    0.5dB

    ---

    ---

    ---

    ---

    Connection (input/output)

     

    BNC/BNC (RS485)

    Connecting terminal

    Connecting terminal

    Operating temperature range

     

    -40°C...+80°C

    Relative humidity:

     

    95% (25°C)

    Earthing via

     

    Earthing screw

    Enclosure material

     

    Aluminum

    Standards

     

    IEC 61643-21; GB 18802.21; YD/T 1542

    Certification

     

    CE(LVD,EMC)

     MAIN CHARACTER 

    1, Green light indicates normal and red light indicates fault for the power supply protection

    2, Integrated protection for power supply lines, control signal lines and video signal lines of the camera

    3, High discharge capacity, low voltage protection level

    4, Quick response, multilevel protection ,small interference to transmission signal

    5, Small volume,for installed on the 35 mm DIN rail.

    INSTALLATION INSTRUCTION 

    1. This Surveillance Camera Surge Protection is connected in series to the protected device.

    2. Mount the Camera Surge Protection on the 35 mm DIN rail.

    3. The out terminal should be connected to the protected devices.

    Note: The “IN” terminal power supply must be installed with a backup fuse;

    4. Earth lead should be connected to the earthing system, ideally using 2.5mm² cable, the cable should be as short as possible

    5. On power up, the green light will be on.

    Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace SPD

     

    INSTALLATION DIAGRAM

    TS-VCP3N-Surveillance-Camera-Surge-Protection-Manufacturer

     

    TS-VCP3N-Surveillance-Camera-Surge-Protection-Warranty

     

    TS-VCP3N-Surveillance-Camera-Surge-Protection-Good-Quality

    WARNING:

    1, The device must be installed by electrically skilled person, conforming to national standards and safety regulations.

    2, It is recommended that installation should be done under power off condition.