Network Surge Arrester
Home » Lightning Products » IT Surge Protection » Network Surge Arrester
Previous : TS-24RJ45/5/8(1000M) Ethernet Surge Suppression
Next : TS-POE Surge Protector
Instruction
♦ TS series POE Surge Arrester with RJ45 interface is designed according to IEC 61643-21; GB 18802.21; YD/T 1542 for protecting POE network device. Normally applied for protecting for IP telephone, IP camera etc.for POE network device.
♦ Product Size
♦ Basic Circuit Diagram
♦ Technical Data
Model |
|
TS-POE5 |
|
RJ45 interface |
Power Supply line |
||
Nominal voltage |
Un |
5V- |
48V- |
Rated voltage (max. continuous voltage) |
Uc |
6V- |
60V- |
Nominal discharge current (8/20) |
In |
2KA (line-line) 2KA (line-PG) |
3KA |
Combination wave (10/700) |
Uoc |
6KA (line-line) 6KA (line-PG) |
--- |
Voltage protection level at In |
Up |
≤60V (line-line) ≤60V (line-PG) |
≤200V |
Response time |
tA |
≤1ns (line-line) ≤1ns (line-PG) |
≤25ns |
Bandwidth |
fG |
165Mbits/s |
--- |
Max. data transmission rates |
Vs |
100Mbits/s |
--- |
Protection lines |
|
1 / 2 / 3 / 6 |
4 / 5 (+). 7 / 8 (-) |
Operating temperature range |
|
-40°C...+80°C |
|
Relative humidity |
|
≤95% (25°C) |
|
Connection (input / output) |
|
RJ45 shield socket |
|
Shield earthing |
|
Screw terminal |
|
Enclosure material |
|
Aluminum |
|
Standards |
|
IEC 61643-21; GB 18802.21; YD/T 1542 |
|
Certification |
|
CE(EMC,LVD) |
♦ MAIN CHARACTER
1, POE surge arrester protects integrated power supply & network signal transmission cables in the twist pairs
2, Good discharge capacity, low voltage protection level
3, Quick response, high transmission speed, low signal attenuation
4, RJ45 connection, easy for installation
INSTALLATION INSTRUCTION 1. This POE Surge Arrester is connected in series to the protected device. 2. The out terminal should be connected to the protected devices. 3. SPD's earthing terminal must be connected to nearby earthing BusBar or the metal earthing enclosure of protected device. 4. After above, you should ensure the circuit is functioning. Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD. |
INSTALLATION DIAGRAM |
WARNING: 1, The device must be installed by electrically skilled person, conforming to national standards and safety regulations. 2, It is recommended that installation should be done under power off condition. |
- CONTACT US
- 0086 13926098193
- 0086 20 28819702 EXT 27806
- [email protected]
- Hongdiyuan Industrial Park, Wufeng Avenue, Linjiang Town, Jiangdong New District, Heyuan, Guangdong,P.R.C.
- http://www.tslpro.com
- +86 13926098193
- F13926098193
- tslpro.tstlp