Network Surge Arrester
Home » Lightning Products » IT Surge Protection » Network Surge Arrester
Previous : TS-POE5 POE Surge Arrester
Next : TS-RJ45POE48 Single-Channel Ethernet Surge Protector PoE & Gigabit
Instruction
♦ TS series RJ45 POE Surge Protector is designed according to IEC 61643-21; GB 18802.21; YD/T 1542 for protecting POE network device. Normally applied for protecting for IP telephone, IP camera etc.for POE network device.
♦ Product Size
♦ Basic Circuit Diagram
♦ Technical Data
Model |
|
TS-POE |
|
RJ45 interface |
Power Supply line |
||
Nominal voltage |
Un |
5V- |
48V- |
Std. Clamp Voltalge |
Uc |
7.5V- |
60V- |
Nominal discharge current (8/20) |
In |
2KA (line-line) 2KA (line-PG) |
2.5KA (line-PG) |
Peak pulse current(10/1000μs) |
Uoc |
300A (line-line) |
200A |
Voltage protection level at In |
Up |
≤60V (line-line) ≤60V (line-PG) |
≤200V |
Response time |
tA |
≤1ns (line-line) ≤1ns (line-PG) |
≤25ns |
Bandwidth |
fG |
165Mbits/s |
--- |
Max. data transmission rates |
Vs |
100Mbits/s |
--- |
Protection lines |
|
1 / 2 / 3 / 6 |
4 / 5 (+). 7 / 8 (-) |
Operating temperature range |
|
-40°C...+80°C |
|
Relative humidity |
|
≤95% (25°C) |
|
Connection (input / output) |
|
RJ45 shield socket |
|
Shield earthing |
|
Screw terminal |
|
Enclosure material |
|
Aluminum |
|
Standards |
|
IEC 61643-21; GB 18802.21; YD/T 1542 |
|
Certification |
|
CE(EMC,LVD) |
♦ MAIN CHARACTER
1, POE network device, protect integrated power supply & network signal transmission cables in the twist pairs
2, Good discharge capacity, low voltage protection level
3, Quick response, high transmission speed, low signal attenuation
4, RJ45 connection, easy for installation
INSTALLATION INSTRUCTION 1. This POE Surge Protector is connected in series to the protected device. 2. The out terminal should be connected to the protected devices. 3. SPD's earthing terminal must be connected to nearby earthing BusBar or the metal earthing enclosure of protected device. 4. After above, you should ensure the circuit is functioning. Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replace the SPD. |
INSTALLATION DIAGRAM |
WARNING: 1, The device must be installed by electrically skilled person, conforming to national standards and safety regulations. 2, It is recommended that installation should be done under power off condition.
|