Network Surge Arrester
Home » Lightning Products » IT Surge Protection » Network Surge Arrester
Previous : TS-RJ45/48/8 Ethernet Surge Suppressor
Instruction
♦ TS Series Multi-RJ45 Surge Protection is designed according to IEC 61643-21; GB 18802.21; YD/T 1542 to protect network equipment from interruption caused by surge current;. Surge Protection with 8 Ports RJ45 interface, all protected by four pairs lines protected.
Mainly used for ethernet 100BaseT/TX/T4、ATM 155MBit/s、100VG-Any-LAN、CDDI、10Base T(IEEE 802.3)、Token Ring(IEEE 802.5)etc.(e.g. Telecom-munication,server, router,computer, and so on).
♦ Product Size
♦ Basic Circuit Diagram
♦ Technical Data
Model |
|
TS-8RJ45/5/8 |
TS-8RJ45/24/8 |
Nominal voltage |
Un |
5V- |
24V- |
Rated voltage (max. continuous voltage) |
Uc |
6V- 4.2V~ |
30V- 21.1V~ |
Nominal discharge current (8/20) |
In |
300A (line-line) 300A (line-PG) |
0.1kA (line-line) 0.1A (line-PG) |
Max. discharge current (8/20) |
Imax |
400A (line-line) 400A (line-PG) |
0.2kA (line-line) 0.2kA (line-PG) |
Voltage protection level at In |
Up |
≤50V (line-line) ≤50V (line-PG) |
≤60V (line-line) ≤60V (line-PG) |
Voltage protection level at 1kV/ms |
Up |
≤ 13V (line-line) ≤ 13V (line-PG) |
≤ 45V (line-line) ≤ 45V (line-PG) |
Capacitance |
C |
≤ 35pF (line-line) ≤50pF (line-PG) |
≤ 16pF (line-line) ≤20pF (line-PG) |
Response time |
tA |
≤1ns (line-line) ≤1ns (line-PG) |
≤1ns (line-line) ≤1ns (line-PG) |
Bandwidth |
fG |
165Mbits/s |
300Mbits/s |
Max. data transmission rates |
Vs |
155Mbits/s |
|
Operating temperature range |
|
-40°C...+80°C |
|
Relative humidity |
|
≤95% (25°C) |
|
Connection (input / output) |
|
RJ45 shield socket |
|
Pining |
|
1/2, 3/6, 4/5, 7/8 |
|
Shield earthing |
|
Metal enclosure |
|
Standards |
|
IEC 61643-21; GB 18802.21; YD/T 1542 |
|
Certification |
|
CE(LVD,EMC) |
♦ MAIN CHARACTER
1, Low voltage protection level;
2, Quick response;
3, Low insertion loss
INSTALLATION INSTRUCTION 1. This RJ surge protection is connected in series to the protected device. 2. The out terminal should be connected to the protected devices. 3. SPD's earthing terminal must be connected to nearby earthing BusBar or the metal earthing enclosure of protected device. 4. After above, you should ensure the circuit is functioning. Regularly inspect the operating status, especially after lightning.Once the communication is off, electrician should check/replace the SPD. |
INSTALLATION DIAGRAM |
WARNING: 1, The device must be installed by electrically skilled person, conforming to national standards and safety regulations. 2, It is recommended that installation should be done under power off condition. |