Information Surge Arrester
Home » Lightning Products » IT Surge Protection » Information Surge Arrester
Previous : TS-SC12 Data Surge Protection Device
Instruction
♦ TS-SD series Data Surge Arrester Device for Information Technology System
INTRODUCTION:TS-SD Series Data Surge Arrester is for installation at LPZ 0B -2 or higher, protecting the RS-422/RS-485 devices against lightning and surge damages, providing coarse and fine protection.
♦ CUSTOM-MADE CIRCUIT、Voltage & Technical Data AVAILABLE
♦ Product Size
♦ Basic Circuit Diagram(TS-SD5)
♦ Basic Circuit Diagram(TS-SD24)
♦ Technical Data
Model |
|
TS-SD5 |
TS-SD24 |
Nominal voltage |
Un |
5V- |
24V- |
Rated voltage (max. continuous voltage) |
Uc |
6V(line/line) 160V(line/PG,SG/PG) 6V(line/SG) |
32V(line/line) 160V(line/PG,SG/PG) 32V(line/SG) |
Nominal discharge current (8/20) |
In |
10 KA |
10 KA |
Max. discharge current(8/20) |
Imax |
20 KA |
20 KA |
Lightning discharge current (10/350) |
Iimp |
1KA |
1KA |
Voltage protection level at 4kV( 1.2/50µS) |
Up |
25V(line/line) ≤800V(line/PG,SG/PG) ≤25V(line/SG) |
60V(line/line) ≤800V(line/PG,SG/PG) ≤60V(line/SG) |
Response time |
tA |
≤4ns(line/line) ≤20ns(line/PG,SG/PG) ≤4ns(line/SG) |
≤4ns(line/line) ≤20ns(line/PG,SG/PG) ≤4ns(line/SG) |
Max. load current |
IN |
100mA |
400mA |
Series impedance per line |
R |
2Ω |
1.5Ω |
Capacitance |
C |
≤300pF(line/line) ≤100pF(line/PG,SG/PG) ≤300pF(line/SG) |
≤1500pF(line/line) ≤100pF(line/PG,SG/PG) ≤1500pF(line/SG) |
Operating temperature range |
|
-40°C...+80°C |
|
Cross-sectional area |
|
Max. 2.5m m2 flexible |
|
Mounting on |
|
35mm DIN rail |
|
Enclosure material |
|
Orange thermoplastic material, UL94-V0 |
|
Standards |
|
IEC 61643-21 & GB 18802.21 |
|
Certification |
|
CE (LVD, EMC) |
♦ MAIN CHARACTER
1, Small size, only 7mm wide module
2, Connected to earth by DIN rail or earthing terminal
3, With shield terminal(direct or indirect to earth)
INSTALLATION INSTRUCTION 1. This data surge arrester is connected in series to the protected device. 2. The IN (1/2, 3/4) terminal should be connected to the single lines input, the OUT (5/6, 7/8) terminal should be connected to the protected devices. 3. There is a earthing terminal in each side, and it is recommended to use the one at output side; earth lead must be connected to the earthing system, ideally using 2.5mm² cable. The cable should be as short as possible. 4. After above, you should ensure the circuit is functioning. Regularly inspect the operating status, especially after lightning. Once the communication is off, electrician should check/replacethe SPD. |
TS-SD5 INSTALLATION DIAGRAM
|
WARNING: 1, The device must be installed by electrically skilled person, conforming to national standards and safety regulations. 2, It is recommended that installation should be done under power off condition. |