    ♦  TS-VCP2  IP Camera Surge Protector is designed to protect power lines and video lines of surveillance devices from surge damages, such as surveillance video receiver and camera and so on.These products are widely used in bank surveillance systems(CCTV system), residential security systems,surveillance devices or school security corporation & roads.

    ♦ Product Size (with BNC connector)

    TS-VCP2-IP-Camera-Surge-Protector-For-sale

     

    ♦ INPUT & OUTPUT with BNC connector

    TS-VCP2-IP-Camera-Surge-Protector-Factory

     

    ♦ INPUT & OUTPUT with RJ45 connector

    TS-VCP2-IP-Camera-Surge-Protector-Cheap

    ♦ Technical Data 

    Model 

    TS-VCP2 

    Protection lines 

    Video Line (BNC) 

    Video Line  

    (RJ45) 

    Power Supply line 

    Nominal voltage 

    Un

    5V- 

    48V-

    220V- 

    48V-

    24V-

    12V-

    Lightning impulse current(10/350)

    Iimp

    0.5KA

    0.5KA

    ---

    ---

    ---

    ---

    Nominal discharge current (8/20) 

    In

    2.5KA(line-shield)

    5KA (shield-PG) 

    2.5KA (line-shield)

    5KA (shield-PG)

    5KA

    5KA

    5KA

    5KA

    Max. discharge current (8/20)

    Imax

    5KA (line-shield) 

    10KA (shield-PG)

    5KA (line-shield) 

    10KA (shield-PG)

    10KA

    10KA

    10KA

    10KA

    Voltage protection level at In 

    Up

    ≤25V (line- shield)

    ≤25V (shield-PG) 

    ≤130V(line- shield)

    ≤130V (shield-PG)

    ≤950V

    (L-N)

    ≤450V

    (L-N)

    ≤300V

    (L-N)

    ≤240V

    (L-N)

    Voltage protection level at 1kV/µs

    Up

    ≤25V (line- shield)

    ≤25V (shield-PG)

    ≤145V(line-shield)

    ≤145V (shield-PG)

    ---

    ---

    ---

    ---

    Response time

    tA

    ≤1ns (line- shield)

    ≤100ns (shield-PG)

    ≤1ns (line- shield)

    ≤100ns (shield-PG)

    ≤25ns

    ≤25ns

    ≤25ns

    ≤25ns

    Bandwidth

    fG

    10MHz

    165MHz

    ---

    ---

    ---

    ---

    Max. data transmission rate

    Vs

    16Mbits/s

    100Mbits/s

    ---

    ---

    ---

    ---

    Series impedance

     

    ---

    ---

    ---

    ---

    ---

    ---

    Insertion lose

     

    0.4dB

    0.4dB

    ---

    ---

    ---

    ---

    Connection (input/output)

     

    BNC socket/plug

    RJ45 socket/plug

    Screw

    Operating temperature range

     

    -40°C...+80°C

    Relative humidity:

     

    95% (25°C)

    Earthing via

     

    Earthing screw

    Enclosure material

     

    Aluminum

    Standards

     

    IEC 61643-21; GB 18802.21; YD/T 1542

    Certification

     

    CE(LVD,EMC)

     

     MAIN CHARACTER 

    1, Integrated protection for power lines and video signal lines of the camera

    2, High discharge capacity, low voltage protection level

    3, Quick response, multilevel protection ,small interference to transmission signal

    INSTALLATION INSTRUCTION

    1. This Camera Surge Protector is connected in series to the protected device.

    2. The out terminal should be connected to the protected devices.

    Note: The “IN” terminal power supply must be installed with a backup fuse;

    3. Earth lead should be connected to the earthing system, ideally using 2.5mm² cable, the cable should be as short as possible

    4. On power up, the green light will be on.

    Regularly inspect the operating status, especially after lightning, once the communication is off, electrician should check/replace the Camera Surge Protector.

     

    INSTALLATION DIAGRAM

    TS-VCP2-IP-Camera-Surge-Protector-In-China

    WARNING:

    1. The device must be installed by electrically skilled person, conforming to national standards and safety regulations.

    2. It is recommended that installation should be done under power off condition.