Coaxial Surge Arrester
Home » Lightning Products » IT Surge Protection » Coaxial Surge Arrester
Instruction
♦ TS-BNC series Coaxial Surge Arrester is designed according to IEC 61643-21; GB 18802.21; YD/T 1542 for protecting coaxial cable transmission devices from interruption caused by surge current, provide reliable protection for coaxial cable transmission devices or video signal transmission devices from surge, operating over voltage and electrostatic discharging.
♦ Product Size
♦ Basic Circuit Diagram(TS-BNC5)
♦ Basic Circuit Diagram(TS-BNC8)
♦ Technical Data
Model |
|
TS-BNC5 |
TS-BNC8 |
Nominal voltage |
Un |
5V- |
8V/+1.5v |
Rated voltage (max. continuous voltage) |
Uc |
8V- |
-10V/+2.1V |
Lightning Impulse Current (10/350) |
Iimp |
0.5KA |
0.5KA |
Nominal discharge current (8/20) |
In |
2.5kA(line-shield) 5kA(shield-PG) |
2.5kA(line-shield) 5kA(shield-PG) |
Max. discharge current (8/20) |
Imax |
5kA(line-shield) 10kA(shield-PG) |
5kA(line-shield) 10kA(shield-PG) |
Voltage protection level at In |
Up |
≤25V(line-shield) |
≤35V(line-shield) |
Voltage protection level at 1kV/µs |
Up |
≤15V(line-shield) ≤600V(line/shield-PG) |
≤15V(line-shield) ≤600V(line/shield-PG) |
Response time |
tA |
≤1ns (line- shield) ≤100ns (shield-PG) |
≤1ns (line- shield) ≤100ns (shield-PG) |
Bandwidth |
fG |
300MHz |
300MHz |
Series impedance per line |
R |
10Ω |
1Ω |
Max. data transmission rates |
Vs |
16Mbits/s |
10Mbits/s |
Operating temperature range |
|
-40°C ~ +80°C |
|
Relative humidity |
|
≤ 95% (25°C) |
|
Connection (input / output) |
|
BNC(socket/plug) |
|
Mounting on |
|
35mm DIN rail |
|
Earthing via |
|
Earthing screw |
|
Shield earthing |
|
Indirectly via integrated spark gap |
|
Standards |
|
IEC 61643-21; GB 18802.21; YD/T 1542 |
|
Certification |
|
CE(LVD,EMC) |
♦ MAIN CHARACTER
1, Good discharge capacity, low voltage protection level
2, Quick response minimize interruption
3, BNC connection, easy for installation
4, Core components are from internationally well known supplier
INSTALLATION INSTRUCTION 1. This BNC Surge Arrester is connected in series to the protected device. 2. Mount the BNC Surge Arrester on 35 mm DIN rail. 3. The out terminal should be connected to the protected devices. 4. BNC Surge Arrester's earthing terminal must be connected to nearby earthing Busbar or the metal earthing enclosure of protected device. Regularly inspect the operating status, especially after lightning, once the communication is off, electrician should check/replace the BNC Surge Arrester. |
INSTALLATION DIAGRAM |
WARNING: 1, The device must be installed by electrically skilled person, conforming to national standards and safety regulations. 2, It is recommended that installation should be done under power off condition. |